FAA Federal Aviation Regulations (FARS, 14 CFR)
FARs > Part 27 > Section 307 - Proof of structure
section 27.305 |
section 27.309

(a) Compliance with the strength and deformation requirements of this subpart must be shown for each critical loading condition accounting for the environment to which the structure will be exposed in operation. Structural analysis (static or fatigue) may be used only if the structure conforms to those structures for which experience has shown this method to be reliable. In other cases, substantiating load tests must be made.
(b) Proof of compliance with the strength requirements of this subpart must include --
(1) Dynamic and endurance tests of rotors, rotor drives, and rotor controls;
(2) Limit load tests of the control system, including control surfaces;
(3) Operation tests of the control system;
(4) Flight stress measurement tests;
(5) Landing gear drop tests; and
(6) Any additional test required for new or unusual design features. (Secs. 604, 605, 72 Stat. 778, 49 U.S.C. 1424, 1425)
[Doc. No. 5074, 29 FR 15695, Nov. 24, 1964, as amended by Amdt. 27-3, 33 FR 14105, Sept. 18, 1968; Amdt. 27-26, 55 FR 7999, Mar. 6, 1990]
  
Current page: FARs > Part 27 > Section 307 - Proof of structure
section 27.305 |
section 27.309

page stats: viewed 463 unique times - last change 25-Jan-2005